PV String and DC Wiring Calculator

Estimate cold-corrected PV string voltage, compare module ratings with one inverter MPPT input, and review DC homerun voltage drop.

Module and string inputs

PV module ratings

V
V
A
A
%/°C

Use the negative coefficient shown on the module datasheet.

%/°C

Use the negative coefficient shown on the module datasheet.

modules
strings
°C
°C
°C
Inverter nameplate limits

Selected MPPT input

V
V
V
A
A
DC homerun estimate

Conductor voltage drop

Resistance reference only; this does not determine an approved PV conductor.

°C
ft

The calculator includes the positive and negative conductors and uses the combined current for this MPPT.

%

This is your design target, not a code limit.

PV string and wiring estimates
1.40% voltage drop
Cold-corrected string Voc439.2 V
STC array power5,760 W
MPPT operating current18.00 A
Array short-circuit current20.00 A
Cold Voc vs. inverter maximumWithin entered limit
Hot/cold Vmp vs. MPPT windowWithin entered limit
Operating current vs. input limitWithin entered limit
Nameplate Isc vs. short-circuit limitWithin entered limit

Estimated Vmp range: 264.0–359.2 V. The check compares your entered module and inverter values only.

Smallest listed copper size meeting the entered voltage-drop target: 12 AWG

Copper conductorDC voltage dropPercent dropTarget
14 AWG11.29 V3.53%Above target
12 AWG7.13 V2.23%Meets target
10 AWG4.46 V1.40%Meets target
8 AWG2.80 V0.88%Meets target
6 AWG1.76 V0.55%Meets target
4 AWG1.11 V0.35%Meets target
3 AWG0.88 V0.28%Meets target
2 AWG0.70 V0.22%Meets target
1 AWG0.55 V0.17%Meets target
1/0 AWG0.44 V0.14%Meets target
2/0 AWG0.35 V0.11%Meets target
3/0 AWG0.27 V0.09%Meets target
4/0 AWG0.22 V0.07%Meets target
250 kcmil0.18 V0.06%Meets target
300 kcmil0.15 V0.05%Meets target
350 kcmil0.13 V0.04%Meets target
400 kcmil0.12 V0.04%Meets target
500 kcmil0.09 V0.03%Meets target
600 kcmil0.08 V0.02%Meets target
750 kcmil0.06 V0.02%Meets target
1000 kcmil0.05 V0.01%Meets target
Design screening onlyThis tool does not select or approve PV modules, strings, conductors, overcurrent devices, or inverters. It does not apply NEC 690 current factors, conductor ampacity correction, rapid-shutdown rules, equipment listings, or all manufacturer limits. Verify the design against the adopted code, module/inverter documentation, and the authority having jurisdiction.

About this calculator

Enter module datasheet values, the number of modules in series, and the number of parallel strings connected to one MPPT input. The calculator estimates cold-corrected string Voc, hot and cold Vmp, nameplate array current, and DC homerun voltage drop.

The inverter comparisons use the limits you enter from its documentation. A result within those limits is not an approval of the complete PV system.

Method and assumptions

Module voltages are treated as STC ratings at 25°C. The temperature-adjusted voltage is estimated with the module’s linear temperature coefficient. Cold-corrected Voc uses the lowest expected ambient temperature; Vmp uses the entered coldest and hottest cell temperatures.

Array Imp and Isc equal the module nameplate current multiplied by parallel strings on the selected MPPT. The DC voltage-drop estimate uses the combined Imp on a two-conductor homerun, Southwire DC resistance values at 25°C, and a linear copper resistance correction for conductor temperature.

The conductor comparison is voltage-drop-only. It does not check NEC 690 current factors, conductor ampacity, OCPD, equipment listing, wire type, disconnects, rapid shutdown, grounding, or all inverter limits. Replace every example input with the project module, inverter, climate, and installation data.

FAQs

Why does the calculator use the lowest ambient temperature for Voc?

A PV module’s open-circuit voltage rises as cell temperature falls. The cold-voltage estimate applies the entered module Voc temperature coefficient to the lowest expected ambient temperature. Verify the temperature method required by the adopted NEC edition and the equipment manufacturer.

Where do I find the module temperature coefficients?

Use the exact module datasheet. Enter a negative Voc and Vmp coefficient, in either percent per degree Celsius or volts per degree Celsius, matching the unit shown by the manufacturer.

What do the inverter current checks mean?

The tool compares nameplate Imp and Isc multiplied by the parallel strings assigned to the selected MPPT input with the inverter limits you enter. It does not apply NEC current factors or size source-circuit conductors or overcurrent devices.

Does the recommended conductor size mean the wire is code-compliant?

No. The comparison only finds a listed copper size that meets the entered voltage-drop target using the selected current, route length, and conductor temperature. Confirm ampacity, temperature correction, wiring method, PV conductor listing, overcurrent protection, terminals, and equipment instructions separately.

Sources